2. Technical Gas Data

a. Gas Specifications

b. Gas Connections

Inlet connection ------------ 1" inch N.P.T.
Inlet supply size ------------ 1" inch N.P.T. (minimum)
Btu/hr input (per dryer) --- 310,000

1) Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must
be
consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column (W.C.)
pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. (liquid propane) gas have the gas valve's internal pressure regulator
blocked open so that the gas pressure must be regulated upstream of the dryer. The
pressure measured at each gas valve pressure tap must be a consistent 10.5 inches water column
(W.C.). There is no regulator or regulation provided in an L.P. dryer. The water column (W.C.)
pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each
dryer.

* D.M.S. (Drill Material Size of equivalents are as follows:)

Natural Gas ..................... # 10 = .1935
Liquid Propane Gas ...... # 33 = .1130

T

YPE OF

G

AS

Natural

Liquid Propane

L.P.

Conversion

Kit

Part Number

Model

Number

BTU Per

Hour

Rating

Qty.

D.M.S.*

Part

Number

Qty.

D.M.S.*

Part

Number

ML-96HS

310,000

3

#10

140836

3

#33

140855

881498

T

YPE OF

G

AS

Natural

Liquid Propane

Manifold Pressure*

3.5 inches W.C.

10.5 inches W.C.

Inline Pressure

6.0 - 12.0 inches W.C.

10.5 inches W.C.

* Measured at gas valve pressure tap when the gas valve in on.