8 troubleshooting – Nilfisk-ALTO 30/BATT/PC/XC User Manual
Page 23
21
ATTIX 30-40-50
1)
Optional accessories / Option depending on model
8 Troubleshooting
Fault
Cause
Remedy
‡ Motor does not start
> Fuse of the mains socket has
blown.
•
Connect mains fuse.
> Overload protection switch
has tripped.
•
Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner
cannot be started again,
contact the Nilfisk-Alto service
department.
> Motor is faulty.
•
Have motor changed by
Nilfisk-Alto Service.
‡
Motor does not run in
automatic mode
1)
> Power tool/pneumatic tool is
defective or not connected
properly.
•
Check that the power tool
works or that the plug is
inserted correctly.
> The power rating of the
electrical tool is too low.
•
Note that minimum power
rating is P>40W
‡
Reduced suction power
> Suction power selected with
suction power control
1)
is too
low.
•
Set suction power in
accordance with section
„Setting suction power“.
> Clogged suction hose/nozzle.
•
Clean suction hose/nozzle
> Tank, disposal bag or filter
bag is full.
•
See "Emptying tank" or
"Replacing disposal bag, filter
bag" sections.
> Filter element is clogged.
•
See section „Cleaning filter
element“ and „Replacing filter
element“.
> Seal between tank and upper
section of vacuum cleaner is
faulty or missing.
•
Replace seal.
> Cleaning mechanism is
defective.
•
Contact Nilfisk-Alto Service.
‡
No suction power during
wet cleaning
> Tank is full.
•
Switch off the cleaner. Empty
the tank.
‡
Voltage fluctuations
> Impedance of power supply is
too high.
•
Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over
7% should not occur if the
impedance at the transfer point
is
≤ 0.15 Ω .