8 Troubleshooting

Fault

Cause

Remedy

‡ Motor does not start

> Fuse of the mains socket has

blown.

Connect mains fuse.

> Overload protection switch

has tripped.

Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner
cannot be started again,
contact the Nilfisk-Alto service
department.

> Motor is faulty.

Have motor changed by
Nilfisk-Alto Service.

Motor does not run in
automatic mode

1)

> Power tool/pneumatic tool is

defective or not connected
properly.

Check that the power tool
works or that the plug is
inserted correctly.

> The power rating of the

electrical tool is too low.

Note that minimum power
rating is P>40W

Reduced suction power

> Suction power selected with

suction power control

1)

is too

low.

Set suction power in
accordance with section
„Setting suction power“.

> Clogged suction hose/nozzle.

Clean suction hose/nozzle

> Tank, disposal bag or filter

bag is full.

See "Emptying tank" or
"Replacing disposal bag, filter
bag" sections.

> Filter element is clogged.

See section „Cleaning filter
element“ and „Replacing filter
element“.

> Seal between tank and upper

section of vacuum cleaner is
faulty or missing.

Replace seal.

> Cleaning mechanism is

defective.

Contact Nilfisk-Alto Service.

No suction power during
wet cleaning

> Tank is full.

Switch off the cleaner. Empty
the tank.

Voltage fluctuations

> Impedance of power supply is

too high.

Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over
7% should not occur if the
impedance at the transfer point
is

≤ 0.15 Ω .