Section vi, Illustrated parts list, 1. general – Duff-Norton SK2463-22 (Modular Actuator Acme Screw) User Manual
Page 10: Illustrated parts list 6-1. general
10
This completes the assembly procedures for actuators not
equipped with limit switches. When assembling an actua-
tor equipped with limit switches, continue with the
instructions below.
27. Apply two or three drops of Loc-Tite No. 35 Extra
Strength Retaining Ring Compound to the shell
bore.
If a new (replacement) limit switch adapter is being in-
stalled, follow steps 28 and 29 below. If a used (previously
spot drilled) adapter is being installed, proceed directly to
step 30.
28. Install the limit switch adapter (29) in the shell (9),
making sure that the adapter bottoms out against
the retaining ring (1). Orient the four tapped holes
in the limit switch adapter to line up with the four
motor mounting holes in the housing flange.
29. Spot drill the adapter (29) in two places and install
the two half dog point set screws (30). Proceed
directly to step 32.
30. Install the limit switch adapter (29) in the shell, align-
ing the spot drilled holes in the adapter with the
tapped holes in the shell.
31. Install the two half dog point set screws (30).
32. Aligning the slot in the limit switch worm shaft with
the pin in the actuator worm, install the limit switch
box on the adapter (29) in the desired position.
Assembly of the actuator is now complete.
Section VI
Illustrated Parts List
6-1. General
This section contains exploded illustrations of Duff-
Norton® Rotating Screw and Translating Tube Modular
Actuators. The numbers adjacent to each of the parts on
the illustrations is the index number. On the parts listed
below, these numbers are keyed to the individual part
names.