beautypg.com

Specifications, General information – CPI Communications DTS1 User Manual

Page 3

background image

3

SPECIFICATIONS

Subject to change without notice.

General Information

The DTC1 DC to Tone convertor converts your existing DC remote control system to the industry standard
sequential tone format used by Motorola, GE, and other manufacturers. You can now, with the addition of
the DTC1 and a CPI TTP series tone termination panel, or equivalent, continue to use your existing DC
remotes after losing your hard-wire lines to a phone company conversion to voice grade circuits. A CPI TTP
series tone termination panel will need to be installed at the transmitter.
The DTC1 provides adjustable audio amplification in both directions as well as a 2175 Hz. notch filter in the
receive audio path to notch out the hold tone from any parallel tone remotes that may be on the system. The
DTC1 is dip switch programmable to recognize one of eight DC current configurations.

Power Requirements

Controls

Line input/output impedance

Control Tones

Tone Duration

Line output level

Notch Filter

DC Control Input Levels

Dimensions, Weight

12VAC @ 300ma. Wall pack provided. Unit may also be
powered directly from a 12 VDC source.

Line Input, Mod Out, Tone Out

600 ohms or 5000 ohms bridged. Balanced input.

Guard tone=2175 Hz, Function tones=F1 - 1950 Hz, F2 - 1850
Hz and Monitor - 2050 Hz, Hold tone=2175 Hz for duration
of PTT

Guard tone = 140 ms ± 1%; Function tones = 40 ms ± 1%

+10 dBm maximum into 600 ohm line, adjustable.

Attenuates 2175 Hz tone from parallel remotes by 50 dB.

“15 mA” = 9.5 -18 mA; “6 mA” = 4.5 - 9 mA; “2.5” = 1.5 - 4
mA

5.5" x 5.5" x 1.5", 2lbs.