Switch settings, Parts list – CPI Communications DTP Series User Manual
Page 3

3
Switch Settings
The following table lists dip switch setting for DTP series.
Dip switch 4 is normally in the OFF position. When in the ON position, The perceived polarity of the phone
lines is reversed.
Modulation output is adjustable from 2 mVRMS to 565 mVRMS with 0 dBm on the phone lines. The phone
lines can be driven to 0 dBm with an RX input level from 88 mVRMS to 880 mVRMS. A 0 dBm level on the
phone line back to the remote can be produced with a mic high input between 2 mVRMS and 565 mVRMS.
Parts List
DTP Series PCB #700-DTPX-200 Rev. B
Reference
Description
CPI Part #
CAPACITORS
C1,18
100uF Elec Rad
208-2021-107
C2,3,5,15,16
.1uF Mono Cer Dip
208-0092-104
C4
10uF Elec Rad
208-4022-106
C6,27
1uF Elec Rad
208-4052-105
C9,10
4.7uF 100V Elec Rad
208-2062-475
C11,12
20pF Cer
208-0001-200
C13,14,17,21,22
.01uf Mono Cer Dip
208-0092-103
C23
180pF Mono Cer Dip
208-0071-181
C24
.047 Mono Cer Dip
208-0092-473
C25
2200pF Mono Cer Dip
208-0071-222
C26
1uF Elec Rad Non-Polar
208-2000-001
C28
2.2uF Elec Rad
208-4052-225
DC Remote Provides
Set Switches
PTT (F1)
PTT (F2)
Mon (F1)
Mon (F2)
1
2
3
DTP1, DTP2
& DTP3
+/- 15mA
OFF
OFF
OFF
+/- 6mA
ON
OFF
OFF
DTP2 & DTP3
+/- 15mA
+/- 6mA
OFF
ON
OFF
+ 15mA
-6 mA
ON
ON
OFF
+/- 6mA
+/- 2.5mA
OFF
OFF
ON
+ 6mA
- 2.5mA
ON
OFF
ON
DTP3
+ 6mA
+ 15mA
- 2.5mA
- 2.5mA
OFF
ON
ON
+ 15mA
- 15mA
+ 6mA
- 6mA
ON
ON
ON