ZC Kit – Large Pellet Insert
(99200149)
Page 4 of 8
10/9/06
© Travis Industries, Inc.
Minimum Enclosure Dimensions
Min.
Max.
Recommended
Height*
29”
31” **
30”
Width
36”
43” **
40”
Depth***
18”
22” ****
20”
* The enclosure height must be raised the same amount as the floor protection (e.g. if you are using 1” floor
protection, the min. height is 30” above the sub-floor).
** The maximum height is determined by the surround panel size (the surround panels are 32” tall).
*** When determining depth, include the facing material (drywall, tile, etc.) – see the illustration below.
**** When venting vertically, there is no maximum depth.
Width
Depth*
Height
When determining the position of the insert, consider
the position of the framing behind the insert relative to
the vent - see the illustration below.
* When determining the depth, include
the facing material (drywall, tile, etc.).
7.5”
Pellet vent requires 3”
clearance to combustibles.
TOP VIEW
NOTE: The enclosure may be
raised. The minimum
distance from the base of the
enclosure to the ceiling is 72”
Ceiling