beautypg.com

Figure 30 – M&G DuraVent DuraPlus® User Manual

Page 19

background image

19

in the event the chimney is to be enclosed.

The other is a flat plate, to be used in cases

when the chimney is not enclosed.

3. Attach Chimney: Place the first Chimney

Section over the flange on the Anchor Plate

with the arrows pointing up. Drill 1/8-inch

diameter holes through the outer sleeve of the

Chimney Section which match the location of

the corresponding holes in the Anchor Plate.

Secure the Chimney Section to the Anchor

Plate with #8 self-tapping sheet metal screws.

4. Finish Chimney: Install the rest as directed

in the Ceiling Supported Installation section,

Steps 4 through 10. Refer to Figure 1 and

Table 4 for chimney height requirements.

Always maintain at least 2 inches of clearance

to combustible materials, and enclose the

chimney where it passes through occupied

areas. Use a Wall Strap for every four feet of

chimney height.

Figure 29

1/2 INCH AIR SPACE

1/2 INCH AIR SPACE ESTABLISHED

BY SPACERS

12 INCH MINIMUM

FLAT ROOF FLASHING

FRAMED

CHASE

ENCLOSURE

NAIL (AS REq)

CAP

SDP-C

STORM COLLAR

(SDP-SC)

FLAT ROOF FLASHING

(SDP-TF)

MUST BE VENTILATED

SPACERS LOCALLY

FRABRICATED (NOT

FURNISHED BY SIMPSON

DURA-VENT)

CHIMNEY

SECTIONS

SDP-P

1/2

Figure 30

CHIMNEY PIPE

SECTION SDP-P

LOW-PROFILE

STARTER SECTION

(REqUIRED IF

CHIMNEY IS

ENCLOSED)

MASONRY

ANCHORS

(4) REq (NOT

FURNISHED)

ExISTING

MASONRY

CHIMNEY

HI-TEMP

SEALANT

SHEET

METAL

SCREWS (4)

REq

ANCHOR PLATE

SDP-AP