Troubleshooting – Graymills Handi-Kleen PH822-A OMI User Manual
Page 4

795-92072
05/08
4
TROUBLESHOOTING
Problem
Probable Cause
Suggested Remedy
Machine unplugged
Plug machine into appropriate wall socket
GFCI tripped
Press RESET button on GFCI
No Machine Function
No power at outlet
Consult plant electrician
Thermostat tripped
Press red thermostat reset button
Heater malfunction
Contact Graymills for more information 1-888-472-9645
Heat Not Working
Heater coil dirty
Clean heater coil (see Recommended Maintenance)
Machine needs to be reset
Toggle RESET switch
Low solution level
Add cleaning solution
Red “RESET” Light ON
Float sensor or control relay
malfunction
Contact Graymills for more information 1-888-472-9645
Valve shut off
Turn valve fully to the left or right to open valve
Clogged filter
Replace filter element (Part #742-09335-1)
Little or No Fluid Flow
Cracked or broken hose
Inspect and replace hose (See parts list)
If your problem is not listed above or problems persist, please contact Graymills for further assistance. 1-888-472-9645