beautypg.com

Maintenance – Silverline 400W Clean Water Pump User Manual

Page 8

background image

www.silverlinetools.com

7

Clean Water Pump

262231

Note: This pump is equipped with an automatic de-aerating device, which
removes air from the pump. If the water level drops below the Air Vent Valve
(3), a small amount of water will penetrate through the Air Vent Valve. This is
not a defect of your pump, but serves to remove air from the pump.

Float switch operation

• After set up is complete and the pump is connected to the power supply,

it will operate automatically and will start pumping provided the water
level is sufficient

• As the water level drops to minimum safe level, the pump will

automatically switch off

Manual operation

• To manually operate the pump, connect to the power supply and

manually lift the Float Switch (2) to switch the pump on

WARNING: Dry-running operation causes increased wear and is to be
avoided. The pump must be immediately switched off when water fails
to flow.
Note: In case the pump was allowed to nearly run dry, it may not start to
pump water again, once water levels are restored. In this case, switch the
pump off for a short time and back on. This will restore proper operation of
the Air Vent Valve (3).

Accessories

• Accessories including water hoses and hose clips are available from your

Silverline dealer. Spare parts can be obtained from toolsparesonline.com

Maintenance

WARNING: Always disconnect the pump from the power supply before
carrying out any maintenance.

General inspection

• Regularly check that all the fixing screws are tight. They may vibrate

loose over time

• Inspect the supply cord of the tool, prior to each use, for damage or wear.

Repairs should be carried out by an authorised Silverline service centre.
This advice also applies to extension cords used with this tool

Cleaning

• Keep your tool clean at all times. Dirt and dust will cause internal parts to

wear quickly, and shorten the machine’s service life

• Remove mud, debris and other dirt after use, and ALWAYS rinse

thoroughly with clean fresh water

Removing obstructions

WARNING: Ensure the pump is disconnected from the power supply before
attempting to remove obstructions. Wear adequate personal protective
equipment, including eye protection and cut-proof gloves.

• In the event of obstructions or dirt inside the Water Inlets (1), the suction

base can be removed for cleaning:
1. Remove the 3 screws in the base, using a suitable Phillips screwdriver

(not included)

2. Pull the base off the pump body
3. Clean around the impeller and inspect for damage

Note: If the impeller is damaged, it must be replaced by an authorised
Silverline service centre.

4. Refit the base and screws, and retighten

Storage

WARNING: DO NOT leave this pump submerged when not in use. Drain
remaining water and dry completely before storage.
• Store this tool carefully in a secure, dry, frost-free place out of the reach

of children

Disposal

Always adhere to national regulations when disposing of power tools that
are no longer functional and are not viable for repair.
• Do not dispose of power tools, or other waste electrical and electronic

equipment (WEEE), with household waste

• Contact your local waste disposal authority for information on the correct

way to dispose of power tools

262231_Z1MANPRO1.indd 7

16/09/2013 15:03