Clean Water Pump
262231
Note: This pump is equipped with an automatic de-aerating device, which
removes air from the pump. If the water level drops below the Air Vent Valve
(3), a small amount of water will penetrate through the Air Vent Valve. This is
not a defect of your pump, but serves to remove air from the pump.
Float switch operation
• After set up is complete and the pump is connected to the power supply,
it will operate automatically and will start pumping provided the water
level is sufficient
• As the water level drops to minimum safe level, the pump will
automatically switch off
Manual operation
• To manually operate the pump, connect to the power supply and
manually lift the Float Switch (2) to switch the pump on
WARNING: Dry-running operation causes increased wear and is to be
avoided. The pump must be immediately switched off when water fails
to flow.
Note: In case the pump was allowed to nearly run dry, it may not start to
pump water again, once water levels are restored. In this case, switch the
pump off for a short time and back on. This will restore proper operation of
the Air Vent Valve (3).
Accessories
• Accessories including water hoses and hose clips are available from your
Silverline dealer. Spare parts can be obtained from toolsparesonline.com
Maintenance
WARNING: Always disconnect the pump from the power supply before
carrying out any maintenance.
General inspection
• Regularly check that all the fixing screws are tight. They may vibrate
loose over time
• Inspect the supply cord of the tool, prior to each use, for damage or wear.
Repairs should be carried out by an authorised Silverline service centre.
This advice also applies to extension cords used with this tool
Cleaning
• Keep your tool clean at all times. Dirt and dust will cause internal parts to
wear quickly, and shorten the machine’s service life
• Remove mud, debris and other dirt after use, and ALWAYS rinse
thoroughly with clean fresh water
Removing obstructions
WARNING: Ensure the pump is disconnected from the power supply before
attempting to remove obstructions. Wear adequate personal protective
equipment, including eye protection and cut-proof gloves.
• In the event of obstructions or dirt inside the Water Inlets (1), the suction
base can be removed for cleaning:
1. Remove the 3 screws in the base, using a suitable Phillips screwdriver
(not included)
2. Pull the base off the pump body
3. Clean around the impeller and inspect for damage
Note: If the impeller is damaged, it must be replaced by an authorised
Silverline service centre.
4. Refit the base and screws, and retighten
Storage
WARNING: DO NOT leave this pump submerged when not in use. Drain
remaining water and dry completely before storage.
• Store this tool carefully in a secure, dry, frost-free place out of the reach
of children
Disposal
Always adhere to national regulations when disposing of power tools that
are no longer functional and are not viable for repair.
• Do not dispose of power tools, or other waste electrical and electronic
equipment (WEEE), with household waste
• Contact your local waste disposal authority for information on the correct
way to dispose of power tools
262231_Z1MANPRO1.indd 7