Description of symbols, Specification – Silverline Digital Clamp Meter User Manual
Page 5

4
GB
Description of Symbols
The rating plate on your tool may show symbols. These represent important
information about the product or instructions on its use.
Wear hearing protection
Wear eye protection
Wear breathing protection
Wear head protection
Wear hand protection
Read instruction manual
Conforms to relevant legislation and safety standards
Environmental Protection
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice
Specification
The following specifications assume a 1-year calibration cycle and
an operating temperature of 18°C to 28°C (64°F to 82°F) at relative
humidity up to 80% unless otherwise noted.
AC Current
(Average sensing, calibrated to rms of sine wave)
Range
Resolution
Accuracy (50Hz - 60Hz)
200A
1000A
Overload Protection:
Jaw Opening:
100mA
1A
±(2.5% of reading ±10 digits)
±(2% of reading ±5 digits
for 800A and below
± (3% of reading ±5 digits)
for other current
1000A within 60 seconds
2" (5cm)
AC Voltage
(Average sensing, calibrated to rms of sine wave)
Range
Resolution
Accuracy (50Hz - 500Hz)
600V
Input Impendance:
Overload Protection:
1V
±(1.2% of reading ±5 digits)
9M
Ω
600V AC/DC on all ranges
DC Voltage
Range
Resolution
Accuracy (50Hz - 500Hz)
600V
Overload Protection:
Input Impendance:
1V
±(1% of reading ±2 digits)
600V DC/peak AC on all
ranges
9M
Ω
Environment
Temperature:
Normal Operation:
Usable Condition:
Storage:
Relative Humidity:
Measurement Method:
Reading Rate:
Polarity:
Overload Indication:
Power Requirements:
Battery Life:
Battery Indication:
Display:
Data Hold:
Weight:
AC Current:
AC Voltage:
DC Voltage:
Resistance:
Continuity Test:
18
˚C-28˚C
0
˚C-50˚C
-20
˚C-+60˚C
battery removed and<80% RH
Max. 80%
Dual slope integration technical
3 reading/sce
Automatic, indicated minus,
assumed plus
Blanking of all digits, except
MSD,decimal point and sign
appropiate
9V Battery
Up to 200 hours typical with
Alkaline
Up to150 hours typical with Zinc
Display indicates LO BAT when
approximately 20% of battery
life remains
LCD 3
1
⁄
2
digit (1999 count)
0.5" high
All function and ranges with this
feature
Approx 11 ounces (310 grams)
0.1A to 1000A
1V to 600V
1V to 600V
200
Ω to 2000MΩ
30+ 20
Ω with audio tone
(64
˚F-82˚F)
(32
˚F-122˚F)
(-30
˚F-140F)
Resistance
Range
Resolution
Accuracy (50Hz - 500Hz)
200
Ω
20K
Ω
Overload Protection:
0.1
Ω
10
Ω
±(1% of reading ±3 digits)
±(1% of reading ±1 digits)
500V DC/rms AC on all ranges
Continuity Test
Range:
Buzzer Sound:
Overload Protection:
200
Ω
30+ 20
Ω
500V DC/rms AC
As part of our ongoing product development, specifications of
Silverline products may alter without notice.
228541_Z1MANPRO1.indd 4
25/10/2011 09:54