Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com

3

The following electrical and refrigeration specifications apply:

d

esign

r

efrigerant

p

ressure

M

odeL

e

LectricaL

t

ype

c

harge

h

igh

L

oW

R134a LC

115V, 1 Ph., 60 Hz., 6.64 AMP

R134a

8.0 oz.

232

88

R22 LC

115V, 1 Ph., 60 Hz., 8.39 AMP

R22

6.75 oz.

285

144

B

M

1

W

B

OR

GR.

115 VOLT

15 AMP. SERVICE

RECOMMENDED

-

+

5

4

3

2

M

OR

B

W

W

B

LEGEND

B = Black

W = White

OR = Orange

ITEM DESCRIPTION
1

Evaporator Fan Motor

2

Condenser Fan Motor

3

Compressor

4

Thermostat

5

Defrost Cycle Control

ELECTRICAL RATINGS

R134a Compressor

115 VOLT 5.0 AMPS

Evaporator Fan Motor 115 VOLT .82 AMPS

Condenser Fan Motor 115 VOLT .82 AMPS

TOTAL AMPS

6.64 AMPS

e

LectricaL

and

r

efrigeration

s

pecifications

ELECTRICAL RATINGS

R22 Compressor

115 VOLT 6.75 AMPS

Evaporator Fan Motor 115 VOLT .82 AMPS

Condenser Fan Motor 115 VOLT .82 AMPS

TOTAL AMPS

8.39 AMPS