Lectrical, Efrigeration, Pecifications – Glastender Lettuce Crisper User Manual
Page 5: Electrical diagram

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
3
The following electrical and refrigeration specifications apply:
d
esign
r
efrigerant
p
ressure
M
odeL
e
LectricaL
t
ype
c
harge
h
igh
L
oW
R134a LC
115V, 1 Ph., 60 Hz., 6.64 AMP
R134a
8.0 oz.
232
88
R22 LC
115V, 1 Ph., 60 Hz., 8.39 AMP
R22
6.75 oz.
285
144
B
M
1
W
B
OR
GR.
115 VOLT
15 AMP. SERVICE
RECOMMENDED
-
+
5
4
3
2
M
OR
B
W
W
B
LEGEND
B = Black
W = White
OR = Orange
ITEM DESCRIPTION
1
Evaporator Fan Motor
2
Condenser Fan Motor
3
Compressor
4
Thermostat
5
Defrost Cycle Control
ELECTRICAL RATINGS
R134a Compressor
115 VOLT 5.0 AMPS
Evaporator Fan Motor 115 VOLT .82 AMPS
Condenser Fan Motor 115 VOLT .82 AMPS
TOTAL AMPS
6.64 AMPS
e
LectricaL
and
r
efrigeration
s
pecifications
ELECTRICAL RATINGS
R22 Compressor
115 VOLT 6.75 AMPS
Evaporator Fan Motor 115 VOLT .82 AMPS
Condenser Fan Motor 115 VOLT .82 AMPS
TOTAL AMPS
8.39 AMPS
ELECTRICAL DIAGRAM