Nstallation – Glastender ST96 User Manual
Page 5
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 • www.glastender.com
4
i
NTroduCTioN
This manual describes the operational features of Slide Top Coolers. Please review this information
before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are fol-
lowed. Thank you for selecting Glastender, Inc. products.
u
TiliTy
r
eQuiremeNTS
aNd
C
oNNeCTioNS
• Electrical: 115 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is recommended. A 6-foot
grounded cord is included.
• Plumbing: None required. Automatic condensate evaporator is included.
u
NCraTiNg
aNd
S
TarT
-u
p
i
NSTruCTioNS
All Slide Top Cooler models are shipped in one carton. These steps should be followed:
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base.
3. Position unit and level and/or seal as required (see page 1-2).
4. Place racks in desired location.
5. Plug into 115 volt AC outlet.
6. Load with bottles or cans and allow time to cool. For best performance, load with pre-cooled
bottles or cans. It is recommended that back-up product be stored in a walk-in cooler.
7. Your Glastender equipment is now ready for use.
S
ealiNg
S
lide
T
op
b
aSe
To
f
loor
To comply with NSF & health codes. The slide top base must be sealed to the floor using NSF listed
sealant. Place bead of sealant along outer edges of the base and remove excess with disposable towel.
o
peraTioN
The Slide Top Cooler is designed to maintain bottles and cans at an operating temperature range of
36°F (2°C) to 40°F (5°C).
Slide Top Coolers include an automatic defrost system. The cooler will defrost every six hours for
approximately 20 minutes. During the defrost, the fan inside the cooler will remain on and the refrigera-
tion system will turn off.
i
NSTallaTioN