ELECTRICAL CONNECTIONS

WARNING:To avoid possible electrical shock be sure electricity is
turned off at the main fuse or breaker box before wiring.

R

NOTE: The Aire Control System is equipped with a learning frequency
function which has 256 code combinations to prevent potential

interference from other remote units.The frequency on your Receiver

and Transmitter units have been preset at the factory. (Fig.13)

No frequency change is necessary, should you desire to install another
fan whithin the same home or area with a separate frequency code
please see the ”frequency interference ”troubleshooting section
of this instruction manual to learn how to change the frequency.

Step 1. Insert Receiver into Hanger Bracket with the flat side of

the Receiver facing the ceiling.(Fig.14)

Step 2. Motor to Receiver Electrical Connections: Connect the

WHITE wire from the fan to the WHITE wire marked”TO MOTOR
N” from the Receiver. Connect the BLACK wire from the fan to the
BLACK wire marked”TO MOTOR L” from the Receiver. Connect the
BLUE wire from the fan to the BLUE wire marked”For Light” from the
Receiver.
NOTE: If your ceiling fan features an UP Light: Connect the ORANGE
wire from the fan to the ORANGE wire marked “ For Up Light ” from
the Receiver. Otherwise disregard this step and proceed to secure all
wire connections with the plastic wire nuts provided.(Fig.15)

Note: Fan must be installed from a maximum distance of 40 feet from
the transmitting unit for proper signal transmission between the