TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Power cord not plugged in

Plug in power cord

Power supply is OFF

Turn power supply ON
and/or replace fuse

Air switch is OFF

Depress the air button

Residential Current Device
(RCD) tripped

Unplug power cord, reset
RCD, check power in
receptacle and plug in
power cord

Pump Does Not Run

Motor over heats

Let the motor cool down

Air tube disconnected

Connect tube to air switch
and air button nipples,
secure

Air tube damage/leaks

Replace tube

Air tube kinked

Remove kink and properly
route the tube

Air button damaged

Replace air button

Pump Still Does Not Run,
Even After Performing #1

Air switch damaged

Replace air switch

Closed valves

Open valves

Low water level in spa bath

Fill spa bath up to the
normal bath water level

Airlock in the plumbing

Bleed air from plumbing

Pump Runs But Low or No
Water Pressure on Jets

Clogged or blocked
plumbing

Open air-venturi control
valve to release air trapped
in plumbing