MEGUIAR'S D157 User Manual
Page 5

D157, Synthetic X-Press Wax (22-19C): D15701
__________________________________________________________________________________________
Page: 5 of 12
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of
a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator
type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapours
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state
Liquid.
Appearance/Odour
Sweet, pleasant odour; Creamy, yellow liquid
pH
7.5 - 8.4
Boiling point/boiling range
>= 93.3 ºC
Melting point
Not applicable.
Flammability (solid, gas)
Not classified
Explosive properties
Not classified
Oxidising properties
Not classified
Flash point
93.3 ºC [Test Method:Pensky-Martens Closed Cup]
[Details:D93-90]
Autoignition temperature
No data available.
Flammable Limits(LEL)
No data available.
Flammable Limits(UEL)
No data available.
Vapour pressure
No data available.
Relative density
0.91 - 1.01 [Ref Std:WATER=1]
Water solubility
Moderate
Partition coefficient: n-octanol/water
No data available.
Evaporation rate
No data available.
Vapour density
No data available.
Viscosity
4.5 - 6.5 Pa-s
Density
0.91 - 1.01 g/cm3
9.2. Other information
Volatile organic compounds (VOC)
14.86 % weight
VOC less H2O & exempt solvents
581.51 g/l
SECTION 10: Stability and reactivity
10.1 Reactivity
This material is considered to be non reactive under normal use conditions
10.2 Chemical stability
Stable.
10.3 Possibility of hazardous reactions
Hazardous polymerisation will not occur.
10.4 Conditions to avoid
Heat.
Sparks and/or flames.