MEGUIAR'S G103 User Manual
Page 5

G103, Scratch X 2.0 (20-191B): G10307
__________________________________________________________________________________________
Page: 5 of 13
a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator
type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapours and particulates
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state
Liquid.
Appearance/Odour
Sweet hydrocarbon odoUr; White, creamy, viscous lotion
Odour threshold
No data available.
pH
8 - 8.8
Boiling point/boiling range
No data available.
Melting point
Not applicable.
Flammability (solid, gas)
Not applicable.
Explosive properties
Not classified
Oxidising properties
Not classified
Flash point
>= 93.3 ºC [Test Method:Pensky-Martens Closed Cup]
Autoignition temperature
No data available.
Flammable Limits(LEL)
No data available.
Flammable Limits(UEL)
No data available.
Vapour pressure
No data available.
Relative density
1.18 [Ref Std:WATER=1]
Water solubility
Moderate
Solubility- non-water
No data available.
Partition coefficient: n-octanol/water
No data available.
Evaporation rate
No data available.
Vapour density
No data available.
Decomposition temperature
No data available.
Viscosity
22,000 - 28 Pa-s
Density
1.18 g/cm3
9.2. Other information
Volatile organic compounds (VOC)
11.00 % weight
SECTION 10: Stability and reactivity
10.1 Reactivity
This material is considered to be non reactive under normal use conditions
10.2 Chemical stability
Stable.
10.3 Possibility of hazardous reactions
Hazardous polymerisation will not occur.
10.4 Conditions to avoid
Heat.