MEGUIAR'S G94 User Manual
Page 5

G94, Carpet Cleaner (XP3-109B): G9416
__________________________________________________________________________________________
Page: 5 of 11
Respiratory protection
Wear respiratory protection if ventilation is inadequate to prevent overexposure. An exposure assessment may be needed to
decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program.
Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for particulates
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state
Liquid.
Appearance/Odour
Pleasant odour; Clear liquid
Odour threshold
No data available.
pH
12.5 - 13.5
Boiling point/boiling range
100 ºC
Melting point
Not applicable.
Flammability (solid, gas)
Not applicable.
Explosive properties
Not classified
Oxidising properties
Not classified
Flash point
> 93.3 ºC [Test Method:Pensky-Martens Closed Cup]
[Details:ASTM D93-90]
Autoignition temperature
Not applicable.
Flammable Limits(LEL)
Not applicable.
Flammable Limits(UEL)
Not applicable.
Relative density
1.00 [Ref Std:WATER=1] [Details:±]
Water solubility
Complete
Solubility- non-water
No data available.
Partition coefficient: n-octanol/water
No data available.
Evaporation rate
No data available.
Vapour density
No data available.
Decomposition temperature
No data available.
Viscosity
No data available.
Density
1 g/ml [Details:±]
9.2. Other information
Volatile organic compounds (VOC)
0.20 % weight
VOC less H2O & exempt solvents
79.22 g/l
SECTION 10: Stability and reactivity
10.1 Reactivity
This material may be reactive with certain agents under certain conditions - see the remaining headings in this section
10.2 Chemical stability
Stable.