M105, Ultra Cut Compound (21-29A): M10501, M10508, M10532
__________________________________________________________________________________________
Page: 5 of 13
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of
a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator
type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapours and particulates
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state
Liquid.
Appearance/Odour
Sweet hydrocarbon odour; Creamy White
pH
8.20 - 8.80
Boiling point/boiling range
193 ºC
Melting point
No data available.
Flammability (solid, gas)
Not classified
Explosive properties
Not classified
Oxidising properties
Not classified
Flash point
Flash point > 93 °C (200 °F)
Autoignition temperature
No data available.
Flammable Limits(LEL)
No data available.
Flammable Limits(UEL)
No data available.
Relative density
1.18 [Ref Std:WATER=1]
Water solubility
Moderate
Partition coefficient: n-octanol/water
No data available.
Evaporation rate
No data available.
Vapour density
No data available.
Viscosity
28 - 38 Pa-s
Density
1.18 g/ml
9.2. Other information
Volatile organic compounds (VOC)
10.93 %
Volatile organic compounds (VOC)
171.10 g/l
SECTION 10: Stability and reactivity
10.1 Reactivity
This material is considered to be non reactive under normal use conditions
10.2 Chemical stability
Stable.
10.3 Possibility of hazardous reactions
Hazardous polymerisation will not occur.
10.4 Conditions to avoid
Heat.