MEGUIAR'S M74 User Manual
Page 4

M74, Cabin Odour Eliminator (20-137A): M7416
__________________________________________________________________________________________
Page: 4 of 10
Occupational exposure limits
Ingredient
CAS Nbr
Agency
Limit type
Additional comments
Formaldehyde
50-00-0
Health and
Safety Comm.
(UK)
TWA:2.5 mg/m3(2
ppm);STEL:2.5 mg/m3(2 ppm)
Propan-2-ol
67-63-0
Health and
Safety Comm.
(UK)
TWA:999 mg/m³(400
ppm);STEL:1250 mg/m³(500
ppm)
Health and Safety Comm. (UK) : UK Health and Safety Commission
TWA: Time-Weighted-Average
STEL: Short Term Exposure Limit
ppm: parts per million
mg/m³: milligrams per cubic metre
CEIL: Ceiling
8.2. Exposure controls
8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapours/spray. If ventilation is not adequate, use respiratory protection equipment.
8.2.2. Personal protective equipment (PPE)
Eye/face protection
The following eye protection(s) are recommended: Safety glasses with side shields.
Skin/hand protection
Skin protection is not required. Select and use gloves and/or protective clothing to prevent skin contact based on the results
of an exposure assessment. Consult with your glove and/or protective clothing manufacturer for selection of appropriate
compatible materials.
Respiratory protection
Select one of the following approved respirators based on airborne concentration of contaminants and in accordance with
regulations:
Half facepiece or fullface air-purifying respirator with organic vapour cartridges and P2 particulate prefilters.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state
Liquid.
Appearance/Odour
Clean, fresh odour; Clear liquid
pH
9 - 9.9
Boiling point/boiling range
>= 82.2 ºC
Melting point
Not applicable.
Flammability (solid, gas)
Not available.
Explosive properties
Not determined.
Oxidising properties
Not determined.
Flash point
> 93.3 ºC [Test Method:Pensky-Martens Closed Cup]
Flammable Limits(LEL)
No data available.
Flammable Limits(UEL)
No data available.