beautypg.com

頁面 9 – MIPRO ACT-70T Wideband Bodypack Transmitter User Manual

Page 9

background image

ERR Message

!

When “ERR” appears in the display it indicates

that an operational error has occurred. Please

refer to the following codes to diagnose which

error you are experiencing.

ERR no01 EEPROM is not being programmed or

internal data error.

ERR no02 For testing only.

ERR no03 The frequency you want to program is

above the switching bandwidth of the

transmitter. Use a receiver with an

appropriate frequency group. (At this time

the microphone is still operating and the

frequency remains unchanged. To clear the

displayed "ERR" message, switch the

handheld transmitter off and on again.)

ERR no04 The frequency you want to program is

below the switching bandwidth of the

transmitter. Use a receiver with an

appropriate frequency group. (At this time

the microphone is still operating and the

frequency remains unchanged. To clear the

displayed “ERR” message, switch the

handheld transmitter off and on again.)

!

“Group” & “Channel” : When both the group

and channel numbers are displayed, it means

that you are using the pre-programmed

frequency of the receiver.

!

“Channel” Only : If “Channel” only is

displayed, it means that you are using a

frequency which is not pre-programmed.

!

Press and hold for 2 seconds to power on & off.

OFF...” - Power Off

!

When the power switch is turned off, the LCD

will show “OFF...” (for Power Off) first and then

the system will shut down and no further

messages will be displayed.

Power Button

OFF...

!

Indicates the power remaining in the transmitter

battery. When the battery has less than 10%

power remaining it must be replaced or

recharged. If an under voltage condition

continues, the LCD will show “OFF...” and the

system will shut down to prevent being overly

discharged.

Battery Status

100%

80%

60%

40%

20%

10%

14

15

Wideband Bodypack Transmitter

Wideband Bodypack Transmitter