4 Installation and Connection

18

4.4.2 Unbalanced

Inputs

Fig. 6: Unbalanced

input stage

Table 2: Standard val-

ues for Rv and 2 x Rv

VDC

Rv

2 x Rv*

12 V ±2 V

330

Ω

680

Ω

24 V ±4 V

680

Ω

1,200

Ω

48 V ±4 V

3,300

Ω

6,800

Ω

* In order to satisfy the IEC 61938 symmetry requirement,

make sure the actual values of the two resistors 2 x Rv
do not differ by more than 0.5%!