Troubleshooting, Service & parts information – Wittco 580 User Manual
Page 11

H & T CABINETS
F-41013 (02-13)
10
TROUBLESHOOTING
SYMPTOMS
POSSIBLE CAUSES
REMEDY
Cabinet not operating
Cabinet not connected to
power source.
Connect cabinet to power source.
No power.
Check circuit breaker
Check GFCI
Moisture problem.
Dry moisture problem.
GFCI or Ground Fault
Circuit Indicator tripped
Shorted element
Contact Authorized Service
Provider.
Pinched/damaged wire.
Contact Authorized Service
Provider.
Damaged power cord.
Contact Authorized Service
Provider.
Defective: element,
thermometer, thermostat,
etc.
Contact Authorized Service
Provider.
Cabinet is connected to
power source, switch is
ON, circuit breaker is ON,
but cabinet is not heating.
Light faulty
Contact Authorized Service
Provider.
Power/Heat Indicator
Light not lit.
Door not shut properly or
needs adjustment
Check door seal and Contact
Authorized Service Provider.
Cabinet does not heat
properly
Defective: element,
thermometer, thermostat,
thermostat requires
adjustment
Contact Authorized Service
Provider.
Fan not operating
ON/OFF switch not ON
Turn ON/OFF switch on
Defective fan
Contact Authorized Service
Provider.
SERVICE & PARTS INFORMATION
To obtain Service and Parts information concerning this model, contact Wittco Service Department at
the address listed on the front cover of this manual or refer to our website:
complete listing of Authorized Service and Parts depots.
Customer Service
414-434-4713
Technical Service
414-434-4716
Service Parts
414-434-4716
When calling for service, have the model number and serial number available.