Electrical Connections

Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting

the unit to power. The specifications on the data plate supersede any future discussion.

The standard display case is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle,

1 Phase properly grounded electrical receptacle. The power cord comes with a 3 prong plug for ground-

ing purposes. Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will

void the warranty, terminate the manufacturers responsibility and could result in serious injury.

The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit

and not plugged into an extension cord.

OPERATION

Initial start up

After satisfying the installation requirements, the refrigerator is ready to start. The refrigerator will start

when the power cord is connected to the required power source. If the compressor does not start when the

unit is initially plugged in, check to make sure that the Temperature Control is not in the “off” position. Allow

the unit to run for two hours before loading it with product. When loading the unit with product, take care not

to block the air flow in the storage area as this would affect the units performance.

Temperature Control

The Temperature Control is located on the top of the cabinet liner and is factory set to maintain an average

cabinet temperature of approximately 35 to 40 Deg F. To obtain colder temperatures turn the Temperature

Control knob clockwise and vice versa. Allow the unit a minimum of one hour to fully respond to a control

setting adjustment.

Defrost

Your Silver King refrigerator is an automatic defrost unit and no additional plumbing is required. Automatic

defrosting is accomplished when frost buildup on the evaporator coil is cleared during compressor ‘off’

cycles. Defrost water is collected in a pan located in the compressor compartment where it is evaporated

into the room air. It is important that the unit be installed level to allow proper drainage of the condensate

water.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued operation

and maximizing the life of the appliance.

Cabinet Surfaces

The cabinet interior and the exterior is stainless steel. These surfaces should be cleaned periodically with

a solution of warm water and mild soap, rinsed and wiped dry with a soft cloth. A stainless steel cleaner can

also be used. Should a surface become stained or discolored, do not attempt to clean with an abrasive

cleanser or scouring pad. Use a soft cleanser and rub with the grain of the metal to avoid scratching the

surface. Do not use chlorinated cleaners. Always rinse well and dry after cleaning.

Condenser

Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the

power supply. To clear the dust, blow compressed air into the condenser fins at the top of the cabinet. This

will need to be done regularly to maintain the compressor warranty!

90052