Temperature Control
The Temperature Control is located on the front of the lower condensing unit. Turn the Temperature Control stem
clockwise to obtain colder cabinet temperatures and vice versa. Allow the unit a minimum of two hours to respond to a
control setting adjustment.
Defrost
The Silver King counter-top drop-in display merchandiser is a manual defrost unit. The unit should be defrosted when-
ever the walls accumulate a frost layer that is 1/4 inch thick. To defrost the unit, either turn the Temperature Control stem
to the off position (fully counterclockwise) or disconnect the Power Cord from the electrical receptacle, and remove the
Lid Assembly. After the frost has melted or come loose from the walls, wipe out the cabinet interior. Do not attempt to
scrape or chisel off the frost as you could do irreparable damage to the unit.
MAINTENANCE
Preventative maintenance is minimal although these few steps are very important to continued trouble free operation
and maximizing the life of your appliance.
Cabinet Surfaces
The cabinet interior and exterior surfaces should be cleaned periodically with a solution of warm water and mild soap,
rinsed and wiped dry with a soft cloth. A good stainless steel cleaner can also be used. Should a surface become
discolored, do not attempt to clean with an abrasive cleanser or scouring pad. Use a soft cleanser and rub with the
grain of the metal to avoid scratching the surface. Do not use chlorinated cleaners on the stainless steel.
Condenser
Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply.
To clear the dust, blow air though the condenser fins or remove the protective screens and brush the dust from the
backside of the condenser.
P/N 90064
MODEL____________________ SERIAL NO.______________________ DATE INSTALLED___________________
Recommended Installation And Ventilation
Openings For Drop-In Models
Front & Rear Vents Are Required For
Proper Air Flow To Condensing Unit
Opening in Counter
Air Flow
10
11
24-1/4
18
20-3/4
21-1/4
21
24