G. specifications, Caution, Nieco corporation - model jf63-bg – Nieco JF63-BG User Manual
Page 33

33
CaUTIon
all electrical connections must be
in accordance with local electrical
codes and any other applicable
codes.
CaUTIon
Do not operate the broiler at gas
pressures other than those stated
here. Doing so will affect the opera-
tion of your broiler.
Nieco Corporation - Model JF63-BG
G. sPeCIfICaTIons
A U T O M AT I C B R O I L E R
Model JF63-BG
DIMENSIONS
Inches
mm
Length
42.34
1075
Height (on stand)
57.62
1463
Width
34.73
882
ENERGY
Gas Models, Natural or LPG:
Average usage:
45,000 BTU/hour; 11,347 Kcal
Connection size: 3/4” NPT
Electric connection: 208V 10.8A 1Ø
WEIGHT
350 lbs 158 Kg
OPTIONS
Legs (no stand)
Spare parts kit
Dual Belt
35.51
902
57.62
1463
49.21
1250
3
BROIL BELT
D
NO.
R
35.47
901
4.80
122
42.34
1075
41.50
BUN BELT
1054
41.96
1066
30.00
762
45.20
1148
B