MAINTENANCE

This section describes the procedures that must be
done by the operator.

WARNING: To prevent injury, always turn

off the switch and remove the electrical

plug from the electrical outlet before

changing the brush, belt, or filter bag and

before leaving the machine.

WARNING: To prevent electrical shock,

always turn off the switch and remove the

electrical plug from the electrical outlet

before doing any repairs or maintenance

to this machine.

WARNING: Belt pulleys can become hot

during normal use. To prevent burns, do

not touch the belt pulley when servicing

the drive belt.

WARNING: Maintenance and repairs must

be done by authorized personnel only.

The Belt to Drive the Brush
This machine uses a round rubber belt to drive the
brush. Check the belt frequently. Replace the belt if
the belt slips on the brush. Remove hair and threads
from the brush roll and the motor shaft pulley before
replacing the belt.

How to Replace the Belt
To replace the drive belt, follow this procedure:

1. Make sure the electrical plug is removed from the

outlet.

2. Put the machine upside down.

3. To remove the bottom plate, turn the two cam

latches on the sides of the plate.

4. Remove the worn belt from the pulley on the motor

shaft. See figure 4.

5. To remove the brush, pull the brush out of the slots

in the frame.

6. Clean the vacuum opening in the base of the

machine.

7. Check the bristles of the brush for wear. If the

bristles are worn, see the section "What to Do

about the Wear of the Brush."

8. Put a new belt around the pulley on the brush.

Align the brush roll pulley with the belt guide. See
figure 5.