5-4. Connecting Tubing between Indoor and

Outdoor Units

a)

Tightly connect the indoor side refrigerant tubing exten-
ded from the wall with the outdoor side tubing. (Fig. 21)

b)

To fasten the flare nuts, apply specified torque as:

Table 5

5-5. Insulation of Refrigerant Tubing

To prevent heat loss and wet floors due to dripping of con-
densation, both tubes must be well insulated with a
proper insulation material.
The thickness of the insulation should be a minimum 5/16"
(8 mm). (Fig. 22)

IMPORTANT

Fig. 21

Fig. 22

Insulation

Min.
5/16"
(8 mm)

Thickness:
min. 5/16"
(8 mm)

Taping the flare nuts

Wind the insulation tape around the flare nuts at the
tube connections. Secondly cover up the tubing connec-
tions with the flare insulation (1/8" (T3, supplied)). Then
wind the other flare insulation (3/16" (T5, supplied)).
Finally, fasten the insulation at both ends with the sup-
plied vinyl ties. (Fig. 23)

Insulation material

The material used for insulation must have good insula-
tion characteristics, be easy to use, be age resistant,
and must not easily absorb moisture.

After a tube has been insulat-
ed, never try to bend it into a
narrow curve because it can
cause the tube to break or
crack.

CAUTION

Fig. 23

Fig. 24

Never grasp the drain or refrigerant connecting out-
lets when moving the unit.

Indoor unit

Outdoor unit

Spanner

Torque wrench

Insulation tape (supplied)

Flare insulation (3/16"(T5, supplied) )

Flare insulation (1/8"(T3, supplied) )

Tube insulation

(not supplied)

Vinyl tie (supplied)

Flare nut

The procedure used for installing
the insulation for both wide and
narrow tubes are the same.

Flare
insulation (supplied)

Vinyl tie (supplied)

Insulation tape (supplied)

Refrigerant tubing
and insulation
(not supplied)

Drain pipe and insulation
(not supplied)

Drain hose insulation
and vinyl tie
(supplied)

Drain hose
and hose band
(supplied)

Tube Dia.

Nut

Tightening Torque

1/4" (6.35 mm)

21/32" (17 mm)

Approx. 120 – 160 lbs·in (140 – 180 kgf·cm)

3/8" (9.52 mm)

7/8" (22 mm)

Approx. 300 – 360 lbs·in (340 – 420 kgf·cm)

1/2" (12.70 mm)

1-1/32" (26 mm)

Approx. 430 – 480 lbs·in (490 – 550 kgf·cm)

5/8" (15.88 mm)

1-5/32" (29 mm)

Approx. 590 – 710 lbs·in (680 – 820 kgf·cm)

This manual is related to the following products: