Electrical cord & plug configurations, Specifications, Electrical ratings – Antunes, AJ UF-420/440 User Manual
Page 6: Dimensions, Specifications (filter cartridges), Uf series water filtration system, Filter cartridge capacities, System capacities

UF SERIES WATER FILTRATION SYSTEM
6
P/N 1010827 Rev. D 04/06
SPECIFICATIONS
Electrical Ratings
CAUTION
All electrical connections must be in accordance
with local electrical codes and any other
applicable codes.
WARNING
ELECTRICAL SHOCK HAZARD.
FAILURE TO FOLLOW THE INSTRUCTIONS IN
THIS MANUAL COULD RESULT IN SERIOUS INJU-
RY OR DEATH.
• Electrical ground is required on this appliance.
• Do not modify the power supply cord plug. If
it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
• Do not use an extension cord with this
appliance.
• Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
Model
Voltage
Watts
Hertz
UF-420
120
10
50/60
UF-440
230
10
50/60
Electrical Cord & Plug Configurations
Letter
Code*
Description
Configuration
C
H
Commercial Cord
Harmonized Cord
(H)C**
CEE 7/7, 16 Amp.,
250 VAC (Assembly
Only).
(C)F***
5-15P, 15 Amp., 120
VAC., Non – Locking
(Assembly Only).
(H)K
Chinese/Australian,
10 Amp., 250 VAC.
(Assembly only)
WHT BLK
GRN
* Used in Model Designation
** Indicates that the Plug comes with a Harmonized Cord
** Indicates that the Plug comes with a Commercial Cord
Filter Cartridge Capacities
Maximum Operating Pressure
100 psig (690 kPa)
Maximum Operating Temp.
104°F (40°C)
Minimum Operating Temp.
40° F ( 4° C)
Maximum Membrane Differential Pressure
45 psi
pH Range
3-10
MWCO
100 kD
System Capacities
Series
UF-420
UF-440
Liters per hour
1500
2000
Liters per minute
25
33.3
Gallons per hour
396
528
Gallons per minute
6.6
8.8