How to use
To select operation mode
AUTO mode - For your convenience
• During operation mode selection the power
indicator blinks.
• Unit selects the operation mode according to the
indoor intake temperature and remote control
temperature.
HEAT mode - To enjoy warm air
• In heat mode, it may take a while for the unit to
warm up.
COOL mode - To enjoy cool air
• To reduce power consumption during COOL
mode, use curtains to screen off sunlight and
outdoor heat.
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle
cooling operation.
To adjust vertical airflow
direction (5 options)
(
Remote control display
)
• Keeps the room ventilated.
• In COOL mode, if AUTO is set, the louver swings
up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal
louver fix at predetermined position.
• Do not adjust the louver by hand.
To achieve temperature
quickly
• This setting enables the desired set temperature
to be reached quickly.
NOTE: POWERFUL and QUIET operations can
not be activated at the same time.
To set the timer
• To turn ON the unit at a preset time. Set the
timer while the unit is OFF.
• To turn OFF the unit at a preset time. Set the
timer while the unit is ON.
Press once to select timer.
Press repeatedly to set your desired
time.
Press once to confirm.
• To turn ON and then turn OFF the unit at
preset time. Set the timers while unit is OFF.
• To turn OFF and then turn ON the unit at
preset time. Set the timers while unit is ON.
Press twice to select timers.
Press / repeatedly to set your
desired time.
Press once to confirm.
• Press the button again to cancel timer
operation.
• The timer will also be cancelled when you
press button.
• The timer indicator of indoor unit will light up
during timer operation.
• When ON Timer is set, the unit may start
earlier before the actual set time in order to
achieve the desired temperature on time.
• If timer is cancelled manually or due to power
failure, you can restore the timer again by
repeating steps above (once power is resumed).
SELECT
SET/CANCEL
A
B
3
3
3
1
1
1
2
2
2
Operation conditions
Use this air conditioner under the following temperature range.
Temperature(°C)
Indoor
Outdoor
*DBT *WBT *DBT *WBT
COOLING
Maximum
32
23
43
26
Minimum
16
11
16
11
HEATING
Maximum
30
-
24
18
Minimum
16
-
-10
-6
NOTICE: •
This model is not suitable for 24 hours non-stopping operation in heating mode below
-10°C. When the outdoor temperature is below -10°C and you use this model out of above
conditions, the outdoor unit might be frozen up and stop operation for protection control.
DBT: Dry bulb temperature
WBT: Wet bulb temperature