beautypg.com

Multi-tasker – Altinex Scan Doubler Card MT106-101 User Manual

Page 9

background image

MULTI-TASKER

8

Ui = Unit ID (i = # from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)

Example:
If one Scan Doubler Card is in slot #2 of unit 3.
Send the command

[VERC2U3]

, and the

Multi-Tasker™ Basic Enclosure will return the
following:

MT106-101 690-0155-003

MT106-101 = card type
690-0155-003 = software version

2. [C]

This command receives the status of the card.

Command Format: [CnUi]

Cn = card ID (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)

Ui = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)

Example:
If there is one MT106-101 card in slot #2 of unit
3 set for NTSC outputs, sending the command
[C2U3] to the Multi-Tasker™ will yield the
following feedback:

INPUT: 640x480; OUTPUT: NTSC C02

INPUT: 640x480

= Input resolution

OUTPUT: NTSC

= Output mode

C02

= card is in slot 2

If there is no card in slot #2 of unit 3, sending
the [C2U3] command will not return any
feedback from either card.

3. [SIGCi]

The Signal Present command tests for the
presence of a signal on the input. After sending
the command, the feedback will be either "1"
signifying a signal is present, or "0" indicating no
signal was detected.

Ci = card number

Example:
To check for the presence of an input signal on
card 4, send the command [SIGC4] and verify

feedback of "1" or "0".

4. [CLR]

This command resets the card configuration to
factory defaults.

Command Format: [CLRCi]

Ci = card ID (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)

Example:

There is an MT106-101 in slot 4 of unit 0. All
controls are set to various levels and the output
is in PAL mode. Sending the command
[CLRC4] will set the level controls to their
default values and place the output in NTSC
format.

5. [ON]

The ON command selects one of four possible
input sources to connect to the output.

INPUT Number

( n )

INPUT Signal

Name

0

S-Video

1

C-Video #1

2

C-Video #2

3

C-Video #3

Command Format: [ONnCiUy]

n

= value from 0 to 3

Ci

= card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100

user’s guide for explanation)

Example:
Connect the S-Video signal input on the
MT106-101 located in slot 4 of unit ID 2 to the
VGA output connector.

[ON0C4U2]

6. [ + ] or [ - ]

These commands allow the user to increase or
decrease the value of the selected attribute.
They must be used immediately following one of
the following STATUS commands.