System temperature setting
Temperature setting
Display
The system controls the temperature for each menu based on the
outdoor ambient temperature.
• To set or change the temperatures, make sure to contact your
nearest authorised dealer.
1 Press and hold for 5 seconds to enter the
temperature range setting mode.
(The display shows SETTING.)
2 Press or to select a menu.
3 Press
to enter the menu.
4 Press or to set the desired temperature.
5 Press to confirm the setting.
• Repeat steps 2 to 5 to set other menus.
User
Checking the temperature range
1 Press and hold for 5 seconds to enter the temperature range setting mode.
2 Press or to select a menu.
• Press
to exit.
Menu
Temperature
setting
Display
Setting of low outdoor ambient temperature.
-15 °C ~ 15 °C
HEAT
Setting of high outdoor ambient temperature.
-15 °C ~ 15 °C
Setting of water outlet temperature at low outdoor ambient
temperature.
25 °C ~ 65 °C
Setting of water outlet temperature at high outdoor ambient
temperature.
25 °C ~ 65 °C
During HEAT mode, the water outlet
temperature is adjusted as is shown the
diagram on the right.
It is performed within the preset temperature
range.
temperature>
max. water temp.
min. water temp.
Setting of outdoor ambient temperature to turn OFF heating
operation during HEAT mode.
5 °C ~ 35 °C
HEAT
Setting of outdoor ambient temperature to turn ON the backup
heater.
-15 °C ~ 20 °C
HEATER
Setting of sanitary water tank temperature.
40 °C ~ 75 °C
TANK
How to use