Product specification – Panasonic CSYE18MKE User Manual
Page 68
68
69
Indoor Unit
Outdoor Unit
Model
CS-YE9MKE
CU-YE9MKE
CS-YE12MKE
CU-YE12MKE
CS-YE18MKE
CU-YE18MKE
COOL
HEAT
COOL
HEAT
COOL
HEAT
Single, 230V,50Hz
Single, 230V,50Hz
Single, 230V,50Hz
Power/Current
[kW]
0.760
0.880
1.020
1.105
1.660
1.615
[A]
3.60
4.10
4.90
5.20
7.90
7.70
Refrigerant
[kg]
R410A
0.780
R410A
0.880
R410A
1.15
Cooling Capacity
[kW]
2.50
3.30
5.00
Heating Capacity
[kW]
3.20
4.00
5.50
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
40
40
42
42
46
46
Conditions
1m Distance
Max. cooling/
heating
operation
47
48
48
50
50
52
Sound power
level
[dB(A)]
56
56
58
58
62
62
63
64
64
66
66
68
Air Circulation
[m
3
/min.]
12.5
13.0
13.5
13.9
14.6
15.3
kg
Product Weight
[kg]
8.0
8.0
7.5
22
26.5
31.5
Dimensions (H x W x D)
[mm]
283 x 803 x 214
283 x 803 x 214
283 x 803 x 214
540 x 780 x 289
540 x 780 x 289
540 x 780 x 289
PRODUCT SPECIFICATION
Test conditions
1.
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
27
19
35
24
HEATING
20
12
7
6
2. Standard piping length: 7.5 m (Includes Indoor Unit piping length).
PH005413 F567885 All.indb 68
2011-2-23 15:12:08