AIR SWING
To adjust airfl ow direction
(
Remote control display
)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver
swings left/right and up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal
louver is fi xed at the predetermined position.
The vertical louver swings left/right after the
temperature rises.
• Do not adjust the louver by hand.
Operation conditions
Use this air conditioner under the following temperature range.
Temperature (°C)
Indoor
CU-RE18QKE
CU-RE24QKE
CU-UE18QKE
DBT
WBT
DBT
WBT
DBT
WBT
DBT : Dry bulb temperature
COOL
Max. 32
23
43
26
43
26
WBT : Wet bulb temperature
Min. 16
11
-10
-
5
-
HEAT
Max. 30
-
24
18
24
18
Min. 16
-
-15
-16
-10
-11
To set the timer
2 sets of ON and OFF timers are available
to turn ON or OFF the unit at different preset
times.
TIMER
SET
CANCEL
ON
OFF
1
2
3
AC
C
CANCEL
3
AC
C
2
1
3
1 Select ON or OFF
timer
Example:
OFF at 22:00
• Each time pressed:
OFF
Cancel
2 Set the time
2
3 Confi rm
SET
TIMER
• To cancel ON or OFF timer, press
ON
or
OFF
to select respective or then press
CANCEL
.
• If timer is cancelled manually or due to power
failure, you can restore the timer again by
pressing
ON
or
OFF
to select respective or
then press
SET
.
• The nearest timer setting will be displayed and
will activate in sequence.
• When ON Timer is set, the unit may start
earlier (up to 35 minutes) before the actual
set time in order to achieve the desired
temperature on time.
• Timer operation is based on the clock set in
the remote control and repeats daily once set.
For clock setting, please refer to Quick guide.