TROUBLESHOOTING

TROUBLESHOOTING

Symptom

Symptom

Cause

Cause

Mist emerges from indoor unit.

• Condensation effect due to cooling process.

Water fl owing sound during operation.

• Refrigerant fl ow inside the unit.

The room has a peculiar odour.

• This may be due to damp smell emitted by the wall, carpet, furniture or

clothing.

Indoor fan stops occasionally during automatic

fan speed setting.

• This helps to remove the surrounding odours.

Operation is delayed a few minutes after

restart.

• The delay is a protection to the unit’s compressor.

Outdoor unit emits water/steam.

• Condensation or evaporation occurs on pipes.

Timer indicator is always on.

• The timer setting repeats daily once set.

Indoor fan stops occasionally during heating

operation.

• To avoid unintended cooling effect.

Cracking sound can be heard during

operation.

• Changes of temperature cause the expansion/contraction of the unit.

Unit switch to FAN operation and air become

humid.

• This happens when the room temperature reaches the set temperature,

operation switches to FAN mode and the humidity increase.

Outdoor unit emits noise during heating

operation.

• This is due to changes infl ow of refrigerant gas when operation stops

and starts.

Operation does not stop immediately after

pressed the OFF/ON button.

• Discharging heat is in process. Operation will stops automatically after

approximately 60 seconds.

Operation stops occasionally. (“DEFROST”

appears on the remote control display)

• The unit is in defrosting mode, and the melted frost is drained from the

outdoor unit.

Airfl ow does not start immediately after

operation is started. (“PRE HEAT” appears on

the remote control display)

• The unit is warming up to provide warm air.

Operation starts after power resumes.

• Auto restart is in function and operates under previous setting.

During dry mode, cold air blow out.

• The unit is running cooling operation with low fan speed to dehumidify

the room.

Fan speed change occasionally during heating

mode.

• The room temperature has reached the remote control setting. When the

room temperature drops again, the fan speed will resume to the remote

control settings.

Outdoor unit emits steam during heating

mode.

• This is due to defrost operation happens at the heat exchanger.

The following symptoms do not indicate malfunction.