English, Setting up the special functions, Select functions and set your desired timer – Panasonic WHSXF12D9E8 User Manual
Page 5
ENGLISH
5
SETTING UP THE SPECIAL FUNCTIONS
SETTING UP THE SPECIAL FUNCTIONS
• After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it.
• The control panel can be used for multiple installations. Some functions may not be applicable to your unit.
• Ensure the operation LED is in OFF condition before setting.
TIMER
OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
HEATER
OPERATION
FORCE
HEATER
ACTUAL
Day display
YES / NO / Temperature display
SETTING / STATUS indicator
Functions*
Timer display
Operation
Mode
Actual Operation
SET
SELECT
CANCEL
SETTING
STATUS
SEARCH
CHECK
SELECT FUNCTIONS AND SET YOUR DESIRED TIMER
1. Press
SET
and
CHECK
simultaneously for 5 seconds to enter special setting mode. “SETTING” and “STATUS” indicator is ON.
2. Press or
to browse functions.
3. Press
SELECT
to enter the function.
4. Press or
to enable YES or disable NO function, or set your desired day and time.
5. Press
SET
to confi rm.
Function *
Operation Mode/
Actual Operation Description
External Thermo Controller (YES / NO)
To set external thermo controller connection.
TANK
Tank Connection (YES / NO)
To set tank connection.
SOLAR
Solar Priority (YES / NO)
To choose the solar use for water tank heat up.
HEAT
Heating Priority (YES / NO)
To choose the heat pump only use for Heating side during HEAT + TANK mode.
HEAT
Heating Heat-up Interval Set
To set timer for Heating during HEAT + TANK mode (0.5hour ~ 10hours).
TANK
Tank Heat-up Interval Set
To set timer for Tank during HEAT + TANK mode (5minutes ~ 1hour 35minutes).
BOOSTER
Booster Heater Delay Time Set
To set delay timer for booster heater to ON if tank temperature is not reached (20minutes ~ 1hour
35minutes).
Sterilization (YES / NO)
To set sterilization, if required.
Sterilization Day & Time Set
To set timer for sterilization (only once a week).
Sterilization Temperature Set
To set temperature for sterilization function (40°C ~ 75°C).
Sterilization Continue Time
To set timer to maintain heating temperature in order to complete the sterilization function
(5minutes ~ 1hour).
CAUTION
CAUTION
Do not use the system
during sterilization
to prevent burnt or
overheat during shower.