beautypg.com

Nilfisk-ALTO NEPTUNE 5 FA 107400337 C User Manual

Page 11

background image

9

1)

Options / model variants

Original instructions

NEPTUNE 5 FA

1. Open cabinet (and service door

if desired - see chapter 3.6, Step
1+2).

2. Turn the twist grip on the safety

control block all the way to the left
(counter- clock wise-direction).

3. Turn the main switch to position

.

4. Select temperature (over 100°C

(212°F)).

For special applications: replace the
standard nozzle with the steam spray
nozzle (accessory).

4.2

Switching on the
cleaner

4.2.1 Cold water operation /

Hot water operation (up
to 100°C)

1. Turn the main switch to posi-

tion

(cold water).

Control electronics accomplishes
a self check.
The Display shows for approx. 1
second „---“.
The motor starts.

is ON.

2. Turn the main switch to posi-

tion

(hot water).

3. Select temperature.
4. Unlock the spray gun and

squeeze trigger.

5. The oil burner will light.
6. Release trigger and lock the

spray gun when not in use.

4.3 Pressure

regulation

(Tornado Lance)

1. Turn the twist grip on the spray

unit:

– High pressure =

clockwise (+) for high pres-
sure

– Low pressure =

counter-clockwise (–) for low
pressure.

4.2.2

Steam operation (over

100°C (212°F))

Beware of hot water and
steam discharge up to
150°C when operating in
steam stage.

NOTE!
The cleaner switches off
automatically twenty seconds after
the spray gun has been closed. To
start the cleaner again, squeeze
the trigger and the machine will
start automatically.

4.4 Pressure

regulation

(VarioPress Gun)

1)

For safety reasons,
never tie back or
wedge open the
trigger of the spray
gun in open
position during

operation. The trigger must be free
to close when released, thus
interrupting the fl ow of the water.

1. Turn the twist grip on the

spray unit:

Water volume

(–)

(+)

min.

max.