COMbIThERM® ES SERIES • ELECTRIC INSTALLATION MANUAL #MN-28897 • 32.
i n s t a l l a t i o n
cONTINUed
ON
NexT
pAge
ERROR CODES AND REASONS (continued)
Error
Code
Display Shows
When does the error occur?
Possible reason
E29
Probe Short to Frame
Activated if one or more of the temperature
sensors were connected to GND for 5 seconds.
• Connection issue at any of the temperature
sensors.
• Temperature sensor shorted to ground/faulty.
E34
DE (Drain) Pump Failure
Activated if water level did not drop below
the low level sensor in the generator during a
steam generator flush.
• Problem with water level probe.
• Scale build-up inside steam generator.
• Scale plugging drain pump.
• Faulty drain pump.
E35
Venting Error
Activated when vent switch reads open (vent
closed) when it should be closed (vent open), or
when it reads closed (vent open) when it should
be open (vent closed).
• Alignment issue between motor cam and
micro switch.
• Connection issue at micro switch.
• Connection issue at control.
• Faulty vent switch.
• Faulty vent motor.
E36
Steam Temp High
Activated when oven temperature probe (N-6)
measures a temperature in excess of 395°F
when running in Steam or Combi mode.
• Water supply is shut off while unit is running
in Steam or Combi mode.
• Plugged or faulty Y-1 solenoid.
• Obstruction between Y-01 solenoid and water
inlet.
E80
ID Error
Control is unable to detect whether unit is gas
or electric.
• Connection issue at X-3 personality jumper.
• Faulty control.
E81
Program Memory Error
Temperature value or time value of a program
step is not allowed.
• Program was generated in °C and control has
been switched to °F.
• Program was generated in °F and control has
been switched to °C.
E82
WP Error
Temperature value or time value of current
cooking algorithm is out of allowed array.
• Delete program and reinstall.
E83
Algo Error
Cooking algorithm sent by operating module
(BM) is unknown to control unit (SM).
• Software versions of control unit and
operating module are incompatible.
• Software error in operating module.
E96
Connection Error
No or bad communication between control unit
(SM) and operating module (BM).
• Connection issue at ribbon cable on display or
relay board.
• Faulty ribbon cable.
• Software versions of control unit and
operating module are incompatible.