beautypg.com

5 cleaning, 6 specifications – AKG Acoustics C414 XLS User Manual

Page 30

background image

30

C 414 XLS / XLII

5 Cleaning

5.1 Microphone

5.2 Windscreen

• Use a soft cloth moistened with water to clean the surface of the microphone body.

• Wash the foam windscreen in mild sudsy water. Do not use the windscreen before it

has dried completely.

6 Specifications

Type:

1-inch large-diaphragm pressure gradient microphone

Polar patterns:

nine, selectable

Open-circuit sensitivity:

23 mV/Pa (-33 dBV ± 0.5 dB)

Frequency range:

20 to 20,000 Hz (see frequency response traces)

Impedance:

≤ 200 ohms

Recommended load impedance:

≥ 2200 ohms

Bass cut filter slopes:

12 dB/octave at 40 Hz and 80 Hz; 6 dB/octave at 160 Hz

Preattenuation pads:

-6 dB, -12 dB, -18 dB (selectable)

Equivalent noise level to IEC 60268-4:

20 dB (0 dB preattenuation)

Equivalent noise level to IEC 60268-4 (A-weighted):

6 dB-A (0 dB preattenuation)

Signal/noise ratio re 1 Pa (A-weighted):

88 dB

Max. SPL for 0.5% THD:

200/400/800/1600 Pa

־ 140/146/152/158 dB SPL

(0/-6/-12/-18 dB preattenuation)

Dynamic range:

134 dB min.

Max. output level:

5 V rms (+14 dBV)

Environment:

temperature: -10°C to +60°C
R.H.: 95% (+20°C); 85% (+60°C)

Powering:

48 V phantom power to IEC 61938

Current consumption:

approx. 4.5 mA

Connector:

3-pin XLR (pin 2 hot)

Dimensions:

50 x 38 x 160 mm / 2 x 1.5 x 6.3 in.

Net weight:

300 g / 10.6 oz.

Patents:

Electrostatic transducer (patents nos. AT 395.225,
DE 4.103.784, JP 2.815.488, US 7,356,151)

This product conforms to the standards listed in the Declaration of Conformity. To order a free copy of the Declaration of
Conformity, visit http://www.akg.com or contact [email protected].

BDA_C414VPL_D030834_Hex 02/27/2009 10:27 Seite 30 (Schwarz/Black Auszug)

This manual is related to the following products: