Electric combination oven/steamer – Alto-Shaam 610ES User Manual
Page 2
#424 - 1/08
D U E TO O N G O I N G P R O D U C T I M P R O V E M E N T
,
S P E C I F I C AT I O N S A R E S U B J E C T TO C H A N G E W I T H O U T N O T I C E
.
www.alto-shaam.com
ELECTRIC COMBINATION OVEN/STEAMER
6 10
ES
C A PA C I T Y
FULL-SIZE PANS:
20" x 12" x 2-1/2"
Six (6)
GN 1/1:
530 x 325 x 65mm
Six (6)
HALF-SIZE SHEET PANS:*
18" x 13" x 1"
Six (6)
ON WIRE SHELVES ONLY
72 lb (33 kg)
MAXIMUM
VOLUME MAXIMUM
: 45
QUARTS
(57
LITERS
)
W E I G H T
NET
285 lb
EST
.
(129 kg)
EST
.
SHIP
415 lb
EST
.
(188 kg)
EST
.
CRATE
40"
X
48"
X
40"
EST
.
DIMENSIONS
: (1016 x 1219 x 1016mm)
E L E C T R I C A L
VOLTAGE
PHASE
CYCLE
/
HZ
AWG
AMPS
kW
at 208
1*
50/60
2 Wire plus ground
40.5
8.4
at 240
AWG 6
47.0
11.2
at 208
3
50/60
3 Wire plus ground
23.5/ph
8.4
at 240
AWG 8
27.0/ph
11.2
at 380
3
50/60
4 Wire plus ground
13.0/ph
8.4
at 415
AWG 12
16.0/ph
11.2
at 440
3*
50/60
3 Wire plus ground
20.0/ph
15.4
at 480
AWG 8
22.0/ph
18.4
*
ELECTRICAL SERVICE CHARGE APPLIES
20
8-
24
0
20
8-
24
0
38
0-
41
5
44
0-
48
0
31-3/8" (796mm)
34-1/16" (864mm)
17-15/16"
(456mm)
7-9/16"
(191mm)
WATER
DRAIN
33-1/8" (840mm)
4-15/16"
(125mm)
S
te
a
m
V
e
n
t
(T
o
p
)
6
0
-9
/1
6
"
(1
5
3
8
m
m
)
Water Drain
(Side Back)
Treated Water
Intake (Bottom)
Untreated Water
Intake (Bottom)
Electrical Connection
(Bottom)
30" (761mm)
4-3/4" (120mm)
2-3/16" (56mm)
(2
9
0
m
m
)
6
-3
/8
"
(1
6
1
m
m
)
41-15/16" (1064mm)
43-7/8" (1114mm)
2" (50mm)
49-1/8" (1247mm)
1
5
-7
/8
"
(4
0
3
m
m
)
1
4
-3
/1
6
"
(3
6
0
m
m
)
3
5
-3
/1
6
"
(8
9
3
m
m
)
2
7
-1
1
/1
6
"
(7
0
2
m
m
)
7
-9
/1
6
"
(1
9
2
m
m
)
Decalcification
Port
1
1
-7
/1
6
"
D I M E N S I O N S :
H x W x D
EXTERIOR
:
35-3/16" x 43-7/8" x 34-1/16" (893mm x 1114mm x 864mm)
EXTERIOR
WITH
RETRACTABLE
DOOR
:
35-3/16" x 47-7/8" x 34-1/16" (893mm x 1216mm x 864mm)
INTERIOR
:
17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm)
*
ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R A N C E R E Q U I R E M E N T S
LEFT
: 6" (152mm)
PLUS SERVICE ACCESS
:
18" (457mm)
RECOMMENDED
20" (508mm)
F R O M H E AT P R O D U C I N G E Q U I P M E N T
RIGHT
: 4" (102mm)
TOP
: 20" (508mm)
FOR AIR MOVEMENT
BACK
: 4" (102mm)
BOTTOM
: 5-1/8" (130mm)
FOR LEGS
COUNTER
-
TOP INSTALLATIONS MUST MAINTAIN
4" (102mm)
MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE
(1)
TREATED WATER INLET
:
3/4" NPT
ONE
(1)
UNTREATED WATER INLET
:
3/4" NPT
LINE PRESSURE
:
30 to 90 psi
2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
FERNCO CONNECTION WITH AIR GAP
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure
that incoming water supply is compliant with the specifications
listed through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant
Inlet Water Requirements
(untreated water)
Free Chlorine
Less than 0.1 ppm (mg/L)
Hardness
Less than 3 gpg (52 ppm)
Chloride
Less than 30 ppm (mg/L)
pH
7.0 to 8.5
Alkalinity
Less than 50 ppm (mg/L)
Silica
Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds)
Less than 60 ppm