beautypg.com

Configuration switch settings, Configuration.switch.settings – Adder Technology Adder TS4 User Manual

Page 13

background image



























1 2

3 4

5 6

7 8

ON

1 2

3 4

5 6

7 8

ON

Configuration switch settings

The underside of the TS4 unit features a block of eight switches which are used
to configure various fundamental settings. When shipped, all switches are set to
OFF, which produces normal operation within the TS4 unit. Further details about
switch settings can be found within sections of this guide dealing with specific
setup issues.

OFF: Normal operation

ON: (while power applied) Reset unit

OFF: Cycle between all system ports

ON: Cycle between active ports only

OFF: Normal operation

ON: Upgrade mode

5

OFF: Normal operation

ON: Synchrony mode

OFF: Normal operation

ON: Auto switch to powered port

,3,4

Reserved

Note: The switch settings (except switch 8) are
consulted by the unit only during its power up
phase, i.e. when power is first supplied by a
keyboard socket of a powered system. Therefore,
change the setting while the unit is disconnected
or use switch 8 to force a reset, whereupon the
other switches will be consulted.