4. Connect the water line from the well pump to the inlet
of the Well-X1
™
.
5. Plumb the outgoing supply to the building's water
supply system or into the water treatment equipment (if
present).
6. Install a blow down tube from the relief valve to a drain
or to within 6" of the floor as required by local codes.
A drip pan connected to an adequate
drain must be installed if leaking or flooding could cause
property damage.
FROM
WELL
TO
SYSTEM
RELIEF
VALVE
BLOWDOWN
TUBE