An identification tag is permanently mounted

on the cabinet.

2.

Plug the unit into a properly grounded

receptacle ONLY. Arcing will occur when

connecting or disconnecting the unit unless

all controls are in the “OFF” position.

3.

Position the unit so the cord is easily accessible

in case of any emergencies. If necessary, a

proper receptacle or outlet configuration, as

required for the unit, must be installed by a

licensed electrician in accordance with

applicable, local electrical codes.

230V:

To prevent an electrical shock hazard between the

appliance and other appliances or metal parts in

close vicinity, an equalization-bonding stud is

provided. An equalization bonding lead must be

connected to this stud and the other appliances /

metal parts to provide sufficient protection

against potential difference. The terminal is

marked with the following symbol.

NOTE:

The appliance must be connected to an

electrical circuit that is protected by an

external GFCI outlet.

I N S TA L L AT I O N

Electrical Installation

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH
OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.

ELECTRICAL

VOLTAGE

PHASE CYCLE

/

HZ

AMPS

kW

CORD

&

PLUG

120V

1

50/60 18.8 2.25

NEMA

L5-30

P

30A, 125V

PLUG

208-240V

at 208

1

50/60

8.4

1.75

NEMA

6-15

P

at 220

1

50/60

8.8

1.94

15A, 250V

PLUG

at 240

1

50/60

9.4

2.25

230V (

AGCY

) 1

50

9.4

2.17

CEE

7/7

16A, 25V

PLUG