6

Faults

Fault

Remedy

Appliance cannot be started

Check if the mains plug is connected.
Socket fuse rating too low, look for proper socket.

Insufficient water quantity

Check fresh water level, refill tank if necessary.
Clean the ball valve in the fresh water reservoir.
Check and ensure that the fresh water reservoir is seated properly on the appliance.
Filter in the fresh water reservoir is plugged, clean filter.
Check hoses for blockages; clean if required.

Insufficient vacuum perfor-
mance

Empty the wastewater reservoir.
Check and ensure that the fresh water reservoir is seated properly on the wastewater
reservoir.
Check seals on the fresh water reservoir, clean if necessary.
Clean the seals between the appliance and the dirt water reservoir and check for tight-
ness, replace if required.
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, replace if required
Suction channel plugged, clean.
Check if the vacuum bar is plugged, remove plug if required

Insufficient cleaning result

Increase brush contact pressure.
Check the brushes for wear, replace if required.
Use brush rollers suited for the type of dirt and floor covering.

Brushes do not turn

Check if foreign matters block the brushes; remove foreign matter if required.
Reduce contact pressure.
Overcurrent protective switch was triggered. The overcurrent protective switch will al-
low the operation after max. one minute.

Appliance vibrates.

Brush rollers are deformed because they were not unloaded by tilting the slider verti-
cally when parking the appliance; replace brush rollers.

Specifications

Power
Nominal voltage

V/Hz

120 / 60

Average power consumption

W

1100

Suction engine output

W

500

Brush engine output

W

1700

Vacuuming
Cleaning power, air quantity

l/s

20

Cleaning power, negative pressure

kPa

10

Cleaning brushes
Working width

mm

400

Brush diameter

mm

96

Brush speed

1/min

650

Dimensions and weights
Theoretical surface cleaning performance

m²/h

400

Fresh/dirt water reservoir volume

l

10

Length (without pushing handle)

mm

520

Width (without vacuum bar)

mm

470

Height (without pushing handle)

mm

380

Weight (without tank contents)

kg

30

Noise emission
Sound pressure level (EN 60704-1)

dB(A)

71

Machine vibrations
Vibration total value (ISO 5349)

m/s²

1,0

8