Karcher B 60 W disc User Manual
Page 9
-
7
1 Wear indicator
2 Vacuum lip
The vacuum lips must be replaced or re-
versed if they are worn down to the wear in-
dicator.
Remove the vacuum bar.
Unscrew the star grips.
Remove the plastic parts.
Remove the vacuum lips.
Insert new or reversed vacuum lips.
Insert the plastic parts.
Screw in and tighten the star grips.
Remove the rubber strip and clean the
channel with a cloth. After cleaning, re-
place the rubber strip evenly.
Lift the cleaning head.
Loosen the lock of the wiper flap.
Push the bearing lid down and remove.
Pull out the brush roller.
Note: The brush rollers must be re-
placed when the bristle length has
reached 10 mm.
Insert a new brush roller.
Reassemble the bearing lid in the re-
verse sequence.
Repeat process on the opposite side.
Lift the cleaning head.
Press the pedal for changing the brush-
es downward beyond its resistance.
Pull the disc brush out of the side below
the cleaning head.
Hold the new disc brush under the
cleaning head, push upward and lock.
Push the appliance forward about 2 m
so that the steering rollers point toward
the rear.
Press the pedal for lowering the clean-
ing head downwards slightly and then
move it to the left. This unlocks the ped-
al. Release the pedal slowly upwards.
The lift arm of the cleaning head will be
lowered.
1 Spring element
2 Locking pin
3 Terminal strip cover
4 Lock of safety pin
5 Excenter lever
Remove the terminal strip cover.
Place the cleaning head halfway in front
of the appliance.
Connect the mains supply cable of the
cleaning head to the appliance.
Attach the terminal strip cover.
Connect the hose couplers on the
cleaning head to the hose on the appli-
ance.
1 Spring element
2 Push handle
Insert the push bow into the cleaning
head intake.
Push the spring elements down and
lock them into place.
1 Excenter lever
2 Locking pin
Open the excenter lever of the slideable
intake on the lift arm.
Press the cleaning head all the way
against the push handle.
Note: The less play the cleaning head
has after being installed, the less vibra-
tion will occur during cleaning.
Move the intake and insert the safety
pin and lock it into place.
Close the excenter lever.
Swivel the water reservoir all the way
down, check the lock.
The removal will take place in the opposite
order of the installation.
Caution
When the cleaning head is removed, the
stability of the appliance can be compro-
mised; ensure a safe stance.
Possibly support the rear to prevent tipping.
Replace or turn vacuum lips
Clean water distribution channel
Replacing the brush rollers
Replacing the disk brushes
Install cleaning head
Dismantling the cleaning head
9