beautypg.com

Technical specifications, Ec declaration of conformity – Karcher K 2 Basic User Manual

Page 15

background image

– 8

Subject to technical modifications!

We hereby declare that the machine described
below complies with the relevant basic safety
and health requirements of the EU Directives,
both in its basic design and construction as well
as in the version put into circulation by us. This
declaration shall cease to be valid if the machine
is modified without our prior approval.

The undersigned act on behalf and under the
power of attorney of the company management.

Authorised Documentation Representative
S. Reiser

Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212

Technical specifications

Electrical connection
Voltage

220-240

1~50/60

V
Hz

Power consumption

6 A

Protection class

IP X5

Protective class

II

Mains fuse (slow-blow)

10 A

Water connection
Feed pressure

0,2-1,2 MPa

Max. feed temperature

40 °C

Min. feed volume

7 I/min

Performance data
Working pressure

8 MPa

Max. permissible pressure

11 MPa

Water flow rate

5,2 I/min

Detergent flow rate

0,3 I/min

Recoil force of trigger gun

10 N

Dimensions and weights
Length

280 mm

Width

176 mm

Height

443 mm

Weight, ready to operate with ac-
cessories

4,7 kg

Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K

<2,5

0,3

m/s

2

m/s

2

Sound pressure level L

pA

Uncertainty K

pA

75

3

dB(A)
dB(A)

Sound power level L

WA

+ Uncer-

tainty K

WA

91 dB(A)

EC Declaration of Conformity

Product:

High-pressure cleaner

Type:

1.673-xxx

Relevant EU Directives
2006/42/EC (+2009/127/EC)
2004/108/EC
2000/14/EC
2011/65/EC
Applied harmonized standards
EN 50581
EN 55014–1: 2006+A1: 2009+A2: 2011
EN 55014–2: 1997+A1: 2001+A2: 2008
EN 60335–1
EN 60335–2–79
EN 61000–3–2: 2006+A1: 2009+A2: 2009
EN 61000–3–3: 2008
EN 62233: 2008
Applied conformity evaluation method
2000/14/EC: Appendix V
Sound power level dB(A)
Measured:

89

Guaranteed:

91

Winnenden, 2012/11/01

CEO

Head of Approbation

15

EN