beautypg.com

Karcher HDS 9-18-4M User Manual

Page 29

background image

– 5

Figure 5

Figure 6

Completely roll off the high-pressure
hose from the hose drum.

Rotate the hose drum until the screwed-
on semibowl is pointing toward the top.
Loosen all three screws and remove the
loosened semibowl.

Figure 7

Unlatch the fastening clamp for the high-

pressure hose and pull the hose out.

Route the new high-pressure hose

through the intended hose guide and

the deflection pulley at the bottom of the

appliance.

Slide the hose nipple all the way into the

knot section of the hose drum and se-

cure with the fastening clamp.

Replace the half bowl.

For connection values refer to technical
specifications

Connect the supply hose (minimum

length 7.5 m, minimum diameter 3/4“) to

the water connection point of the ma-

chine and at the water supply point (for

e.g. a tap).

Note: The supply hose is not included.

If you want to suck in water from an exter-
nal vessel, the following modification is
necessary:
Figure 8

Remove the system care bottle.

Release and remove the cover of the

system care.

Remove water connection from the fine

filter.

Unscrew the fine filter from the pump
head.

Figure 9

Remove the system care reservoir.

Unscrew the top supply hose to the
swimmer container.

Figure 10

Connect the top supply hose at pump
head.

Replug the rinse line of the detergent
dosing valve.

Connect suction hose (minimum diame-
ter 3/4“) with filter (accessory) to the
water connection point.

Max. suck height: 0.5 m

Until the pump sucked in water, you should:

Set the pressure/quantity regulation at
the pump unit to maximum quantity.

Close the dosing valve for the detergent.

ƽ

Danger

Never suck in water from a drinking water
container. Never suck in liquids which con-
tain solvents like lacquer thinner, petrol, oil
or unfiltered water. The sealings within the
device are not solvent resistant. The spray
mist of solvents is highly inflammable, ex-
plosive and poisonous.
Note: Assembly in reverse order. Ensure
that the solenoid valve cable on the reser-
voir of the system care is not pinched.

For connection values, see technical
data and type plate.

The electrical connections must be
done by an electrician according to IEC
60364-1.

ƽ

Danger

Danger of injury by electric shock.

Unsuitable extension cables can be
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:

Always unwind extension lines com-
pletely.

The plug and coupling of the extension
cable used must be watertight.

Installing the replacement

high-pressure hose (appliances

without hose drum)

Installing the replacement

high-pressure hose (appliances

with hose drum)

Water connection

Suck in water from vessel

Power connection

29