Transport storage maintenance and care – Karcher MIC 34C User Manual
Page 15
![background image](/manuals/433683/15/background.png)
– 5
Note
Use normal glycol-based anti-freezing
agents for automobiles.
Observe handling instructions of the anti-
freeze agent manufacturer.
Î
Operate device for max. 1 minute until
the pump and conduits are empty.
1 Hose coupling
2 High-pressure cleaner
3 Safety pin
Î
Take the high pressure cleaner out of
operation.
Î
Disconnect the high pressure cleaner
hoses from the MC 50.
Î
Unlock the safety bolt by turning it and
pull it out toward the side.
Î
Pull the high pressure cleaner out of the
square pipes of the MC 50.
Î
Slide in the safety bolt and lock it by
turning it.
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
Î
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
ƽ
Danger
Risk of injury by inadverently starting appli-
ance. Switch the MC 50 off prior to working
on it and remove the ignition key.
Note
Please dispose off used oil only in the col-
lection points provided for them. Please
hand over old oil, if any, only at such plac-
es. Polluting the environment with used oil
is a punishable offence.
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
Î
Check all hydraulic hoses and connec-
tions and ensure that they are leak-
proof.
Î
Check the high pressure hose for dam-
ages (risk of bursting).
Please arrange for the immediate ex-
change of a damaged high-pressure
hose.
Î
Check appliance (pump) for leaks.
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.
Î
Check oil level Please contact Custom-
er Service immediately if the oil is milky
(water in oil).
Î
Clean the sieve in the water connection.
Unpressurize the appliance.
Unscrew lid with filter.
Disconnect the high pressure clean-
er from the MC 50.
Transport
Storage
Maintenance and care
Safety inspection/ maintenance
contract
Before each use
Weekly
15
EN