Tabelle, Tabellenkopfzeile, Tabellenreihe – Karcher BD 50-40 RS Bp User Manual
Page 6: Troubleshooting, Tabellenhaupttext, Grafik, Appliance cannot be started, A step on the standing platform, Do not press the accelerator pedal, B release emergency-stop button by turning
![background image](/manuals/433596/6/background.png)
QUICKSTART
5.964-039.0 02/11
Troubleshooting
1
A
D
B
E
C
F
Appliance cannot be started
A
Step on the standing platform.
Do not press the accelerator pedal.
B
Release emergency-stop button by turning.
C
Set main switch to “1”.
D
Unplug the charger from the mains.
E
Battery depleted.
Charge battery.
F
Close the solenoid brake. To do this, press
the lever of the solenoid brake all the way up
to the stop.
2
A
B
C
Device does not drive or drives only slowly
A
Release accelerator pedal, turn the key
switch to "0", turn the key switch to "1", press
the accelerator pedal.
B
Reset fuse of control system.
C
Battery depleted.
Charge battery.
3
A
D
G
B
E
C
F
No or inadequate suction power
A
Empty the dirt water reservoir.
B
Reset fuse of suction turbine.
C
Clean the seals between dirt water reservoir
and top of the appliance and check for leaks,
replace if required.
D
Clean the vacuum lips on the vacuum bar,
turn or replace if required
E
Check suction hose for blockages; clean if
required.
Check connection between suction hose and
suction bar and suction hose and wastewater
tank.
F
Clean the floater in the dirt water tank.
G Check and clean the waste water reservoir
sieve.