– 3

Always use spray-protected extension
cables.

The connection between the power
cord and extension cable must not lie in
water.

For connection values refer to technical
specifications.

1 Power switch

Set the appliance switch to "0".

Insert the mains plug into the socket.

ƽ

Danger

Risk of electric shock.

Never wrap the mains cable around
your body or your neck.

Do not let the mains cable come in con-
tact with the rotating brushes or rotating
pads.

1 Power switch
2 Rotary knob

Set the appliance switch to "1".

Adjust the brush speed via the rotary
knob.

Caution
Risk of damage to the floor covering. Do
not operate the appliance on the spot.
Do not start the appliance while dry on sen-
sitive floors.

Apply detergent solution to the surface
to be cleaned or open the faucet on the
detergent tank (accessory).

Move the appliance over the surface to
be cleaned.

Do not press the appliance down onto
the surface to be cleaned. Its intrinsic
weight provides sufficient brush contact
pressure.

Repeat process for severe contamina-
tion.

Afterwards, pick up the wastewater with
a wet vacuum or a cloth.

Recommendations regarding speed set-
ting, acessories and detergents for several
types o application.

Speed 350...470

Brush, red

RM 69 ASF

Speed 350...470

Brush, green

RM 752

Speed 470

Pad drive plate, pad, red

RM 748

Speed 470

Pad drive plate, pad, crystalising

RM 749

Speed 350

Brush, blue

RM 768

Operation

Application

Basic cleaning

Basic cleaning, decoating

Cleaning

Crystalising

Shampoo the carpet

12

EN