beautypg.com

Operation – Karcher BP 6 Deep Well User Manual

Page 16

background image

– 3

For safety reasons, we rec-

ommend that you operate the

appliance only via a earth-

leakage circuit breaker (max.

30 mA).

The electrical connection of

the system may only be per-

formed by a qualified electri-

cian. Please follow the re-

spective national regulations!

This appliance is not intended

for use by persons with limit-

ed physical, sensory or men-

tal capacities or lacking expe-

rience and/or skills, unless

such persons are accompa-

nied and supervised by a per-

son in charge of their safety

or they have received precise

instructions on the use of this

appliance and have under-

stood the resulting risks.

Children may only use this

appliance if they are over the

age of 8 and supervised by a

person in charge of their safe-

ty, or if they have received in-

structions on the use of this

appliance and have under-

stood the resulting risks.

Children must not play with

this appliance.

Supervise children to prevent

them from playing with the

appliance.

Cleaning and user mainte-

nance must not be performed

by children without supervi-

sion.

1 Check valve (pre-assembled)
2 Connection G1 (33.3) internal

thread

3 Switch cabinet/ remote control
4 Fuse
5 On / Off switch
6 Power cord with plug
7 Fastening rope
8 Spacer foot
9 Intake grille/ pre-filter
10 Connection adapter for pumps G1
11 Hose connection pieces 1" and 3/4"
12 Hose clip
13 Eyelet for fastening rope

In order to ensure the faultless opera-
tion of the appliance, the following pre-
conditions must be fulfilled:

Minimum diameter of the well pipe:
15 cm

The aquifer is large enough to en-
sure the water supply to the pump.

Note:
Use filtering tubes to detain

coarse soiling.

Caution
Risk arising from improper bore.

Have an expert drill the bore.

Operation

Description of the Appliance

Preconditions

16